Product advantages
Outstanding function and accuracy
You will be thrilled with this new pyranometer. Selected silicon measuring cells ensure outstanding performance and accuracy. The dose level indicator is already integrated and, together with the two knurled screws, ensures easy alignment and adjustment.
- Measuring range 0...1400 W/m2
- Output 0...50 mV (passive)
- Protection class IP67
- Fully assembled with a spirit level for easy leveling
- Simple and quick leveling and installation
- Knurled screws for quick alignment
Facts, figures and data
Everything at a glance
| Professional Line | 16106 |
|---|---|
| ID No. | 00.16106.000000; Version 00.16106.000080 (0...10 V) |
| Measuring range | Irradiance 0...1400 W/m2 |
| Accuracy | < 4% at 1000 W/m2 at 22 °C (against Secondary Standard Pyranometer) |
| Response time | < 1 sec. |
| Spectral response | 350...1100 nm |
| Output | Analog (passive out) 0...50 mV = 0...1400 W/m2 |
| Range of application | Temperature: -40...+60 °C |
| Supply voltage | Version 00.16106.000080: 12...24 VDC; polarity, short-circuit, and overload protection in the supply area |
| Current consumption | Version 00.16106.000080: typically 7 mA |
| Dimensions | Ø 80 mm; H 46 mm |
| Housing | Aluminum/ABS |
| Protection class | IP67 |
| Weight | Approx. 150 g |
| Cable | 2 m; PUR cable, UV and heat resistant up to 90 °C, UL approved |
| Options (order separately) | 00.08763.055002 (8763 S) Two-channel transducer for radiometer |
Ser[LOG] Plus Data Logger
Ser[LOG] Plus is the most versatile data logger. Thanks to its convertibility through configuration and scaling, you can easily adapt the Ser[LOG] Plus to the specific challenges of your daily measurement tasks.
Overview:
- Serial and analog sensors can be connected
- Handles up to 60 parameters
- Many state-of-the-art communication interfaces
- Extensive sensor library, can be freely configured and scaled by the user
- Formula collection and free formula parser
- Alarm system for 10 warning channels using built-in and external relays
- Wide range of options for exchanging information
- Interference-proof due to shielded aluminum housing
- User-friendly with free access to all terminals and controls