rain[e] Modbus

Weighing precipitation sensor

High resolutionPrecipitation eventsRain intensityPrecipitation amountWeighing tipping bucketModbus RTU
rain[e] Modbus · Weighing precipitation sensor

rain[e] Modbus

Weighing precipitation sensor

Applications

  • professional meteorological applications
  • building automation
  • photovoltaic systems
  • industrial meteorology
Gary NagyGary Nagy

Your contact person:
Gary Nagy
+49 551 4958-343
gnagy
(at)lambrecht.net

Contact

Latest weighing technology...

combined with a self-emptying collecting system allows the rain[e] a high resolution and high precision at a very small construction volume. Already the first drop will be measured! The rain[e] is ideal to setup new measurement network as well as addition to an existing rainfall measurement network. The Modbus RTU interface simplifies sensor installation and integration into networks.  

  • amazing resolution and accuracy
  • checking of sensors with tipping bucket and other weighing systems
  • compact and robust construction with a very low weight
  • all-metal housing, weatherproof and durable
  • best connectivity by several interfaces
  • installation and maintenance are very simple
Professional Line
rain[e] Modbus
Id-No.:
00.15184.000100 rain[e] Modbus, unheated • 00.15184.400100 rain[e] Modbus, heated
Measuring range:
(0.005…∞ mm) without limitation
Amount of accuracy:
2 %
Amount of Resolution:
0.001 mm (pulse output: 0.01 mm)
Intensity range:
0…10 mm/min resp. 0…600 mm/h
Intensity of resolution:
0.001 mm/min resp. 0.001 mm/h
Output:
RS-485 (ASCII protocol, TALKER protocol) • Modbus RTU (default)
2 Pulse-Outputs for linearised, bounce-free output signal
Status-Output (configurable, e.g. rain yes/no or heating on/off)
Analogue output 0/4...20 mA (0...2.5/5 V)
Collection surface:
200 cm2
Environmental conditions:
0...+70 °C (unheated), -40...70 °C (heated, no icing, no snowdrift)
Supply voltage:
9.8...32 V DC unheated
24 V DC / 2 heating circuits: 80 W (funnel) and 60 W (outlet / tipping bucket)
Power consumption:
max. 45 mA at 24 V power supply and analogue output
typ. 7.5 mA at 24 V power supply and deactivated analog output
typ. 12.5 mA at 12 V
Target temperature (heating):
+2 °C funnel surface temperature
Measuring principle:
weighing with automatic self emptying
Dimensions:
292 mm x 190 mm (H x D)
Protection class:
IP67
Weight:
approx. 2.5 kg
Standards:
WMO-No. 8 • VDI 3786 Bl. 7 • EN 61000-2, -4 • EN 61000-4-2, -3, -4, -5, -6, -11 • NAMUR NE-21
Accessories (order separately):
00.15091.600XXX Windshield according to Tretyakov for measuring height 1 m, 1.5 m and 2 m
32.15180.021010 bird defense ring
32.14567.060010 sensor cable, 15 m, 4 pole, M12 plug
32.14567.060000 sensor cable, 12 m, 4 pole, M12 plug
met[LOG] with met[APP] · Data loggermet[LOG] with met[APP] Data logger

The data logger met[LOG] and its browser app met[app] quickly and easily transfer your climate data into your network (LAN). The met[LOG] has an autoconfiguration via plug & play for the uncomplicated commissioning of the serial LAMBRECHT meteo sensors.

 met[APP]

The browser app which is integrated in the met[LOG] for easy visualisation of the current climate data in your network. Platform-independent on your PC, tablet or smartphone.

  • displays the instantaneous values of your LAMBRECHT meteo station
  • exports the measured values stored by the met[LOG]
  • configures the met[LOG]

Features and advantages:

  • real-time access to measurement data via integrated web server, visualised in your browser with met[APP]
  • met[LOG] calculates trends and patterns, and automatically performs corrections based on altitude and air pressure
  • thanks to its digital outputs the met[LOG] immediately issues a warning or raises an alarm
  • plug & play · auto-configuration by push of a button allows full working capability within seconds
  • various combinations are possible: 7 interfaces allow connection of 4 analog and 3 serial sensors
Read more
Ser[LOG] · Data loggerSer[LOG] Data logger

The Ser[LOG] system family allows you the greatest possible freedom for customizing your measurement tasks: extensibility due to modular design,  high flexibility due to a variety of configuration options and many possibilities through state-of-the- art communication interfaces

Ser[LOG] can be extended to a total of 3 AnDiMod analog/digital measuring modules. Available then up to 36 differential analog channels and 11 digital channels.

  • extensive sensor library
  • formulary and free formula parser
  • integrated alarm system for 10 alarm outputs via built-in and external relays, email, SMS
  • interference-proof due to high-quality, shielded aluminium housing
  • user-friendly with free access to all connections and controls
Read more