Product advantages
Integrated weather station for military use
The EOLOS-NBC is an integrated, military-grade weather station for use in NBC (nuclear, biological, chemical) scenarios. It was developed specifically for mobile platforms and reliably provides mission-critical weather and environmental data even under extreme environmental and operational conditions. The EOLOS-NBC thus supports informed situation assessments, operational decisions, and protective measures in military operations and safety-critical applications.
- Reliable data for NBC operations
- Six measurement parameters in one compact system: wind speed, wind direction, air temperature, relative humidity, air pressure, and dew point temperature (calculated)
- Robust and proven in extreme conditions
- Low maintenance for high operational availability
Facts, figures and data
Everything at a glance
| Professional Line | EOLOS-NBC |
|---|---|
| Ident-No. | 00.16433.602012 |
| Measuring range wind direction | 0...360° (0° when there is no wind and when there is wind, NORTH = 360°) |
| Measuring range wind speed | 0...60 m/s (limited by firmware) |
| Air temperature measuring range | -40...+70 °C |
| Temperature measuring range | Ground temperature (ground temperature sensor, external): -40...+110 °C |
| Measuring range rel. humidity | 0...100% RH |
| Air pressure measuring range | 500...1100 hPa |
| Wind direction accuracy | ± 5° |
| Wind speed accuracy | RMS: ± 0.2 m/s ± 3% up to 10 m/s ± 0.5 m/s ± 3% in the range from 10 to 40 m/s ± 0.5 m/s ± 5% in the range from 40 to 60 m/s |
| Air temperature accuracy | ± 1 °C at wind speeds (v) > 2 m/s |
| Temperature accuracy | Ground temperature (ground temperature sensor, external): ± 1 °C |
| Relative humidity accuracy | ± 3% (10...90%) / ± 4% (0...100%) at wind speeds (v) > 2 m/s |
| Air pressure accuracy | ± 0.5 hPa at 25 °C / ± 2 hPa (-40...+85 °C) |
| Wind direction resolution | 1° |
| Wind speed resolution | 0.1 m/s |
| Air temperature resolution | ± 0.1 °C |
| Resolution Temperature | Ground temperature (ground temperature sensor, external): 0.1 °C |
| Resolution rel. humidity | 0.5% RH |
| Air pressure resolution | 0.1 hPa |
| Input voltage | Typically 24 VDC (18...32 VDC) |
| Protocols | NMEA 0183 (interface standard); $WIMWV; $WIMHU; $WIMMB; $WIMTA |
| Interface | Transmission rate: 4800 baud Repetition rate: 1 complete sequence of data sets per second (1 Hz) Transmission parameters: 8 data bits, no parity bit, 1 stop bit |
| Operating conditions | Operating temperature: -40...+70 °C Storage temperature: -55...+95 °C |
| Power consumption | Max. 2.5 A |
| Dimensions | H 388 mm; Ø 120 mm; mast adapter 50 mm diameter |
| Housing | Device housing: aluminum; matte black, RAL 9005 Sensor head: black (hard anodized) Lamellae: white |
| Weight | 2.5 kg |
| Standards and norms | • NMEA 0183 • Design standard: VDE 0100 • Low voltage standard: 72/23 EEC • EMC/EMI: DIN EN 60945 and DIN EN 61000-4-2, 3, 4, 6, 11 Salt spray: EN 60945 • Protection class: DIN EN 60529 • Vibration: BV 0240 |
| Accessories (order separately) | 32.16420.066100 Cable 10 m; with 12-pin bayonet plug; assembled |