Product advantages
Reliable measurements for precise environmental monitoring
The 8096 sensor is a precise measuring device for relative humidity and temperature, suitable for meteorology and industrial applications. It features a capacitive measuring element that is protected from air pollutants by a membrane filter. With energy-saving electronics, it offers high accuracy and long-term stability when used correctly.
- Temperature measuring element: Pt100 1/3 DIN
- Capacitive humidity measuring element
- Special resistance to environmental influences
- High accuracy and long-term stability
Facts, figures and data
Everything at a glance
| Professional Line | 8096 |
|---|---|
| Ident-No. | 00.08096.230402 Standard version 00.08096.330402 Shock and vibration-tested precision measuring device according to BV0230/0430 and BV0440/0240 |
| Air temperature measuring range | -40...+70 °C |
| Measuring range rel. humidity | 0...100% relative humidity |
| Air temperature accuracy | ± 0.1 °C, 1/3 DIN IEC 751 Class B |
| Relative humidity accuracy | ± 2% RH at: 5...95% RH; +10...+40 °C (at > 0.5 m/s); Plus: < 0.1% RH/°C at: < +10 °C; > +40 °C |
| Response time | Humidity: < 20 s (without wind and without filter, otherwise at 1.5 m/s: 1.5 min) |
| Output | Humidity: 0...1 V DC = 0...100 % RH; min. load resistance ≥ 2 k Ohm Temperature: Pt100 (4-wire circuit) |
| Areas of application | 0...100% RH; -40...+70 °C |
| Supply voltage | 6...30 V DC |
| Power consumption | < 1 mA |
| Measuring elements | Humidity: capacitive; Temperature: Pt100 1/3 DIN (DIN EN 60571); IEC 751 Class B (± 0.1 °C) |
| Housing | Stainless steel; IP 65; sensor filter area IP 40; sintered filter for outdoor use |
| Weight | Approx. 0.3 kg |
| Standards and norms | EMC: DIN EN 60945 - Chapters 9, 10 |
| Cable | 3.3 m; permanently connected |
| Accessories (order separately) | 00.08141.600000 Sensor shelter with natural ventilation 00.08141.600004 Sensor shelter with artificial ventilation |
Sensor shelter with natural ventilation
All weather...! Weather and radiation protection with natural ventilation to protect sensors for measuring the relative humidity and temperature of the air.
- Natural ventilation of the sensors
- No return of the heated air to the ventilation circuit
- Light transmission and radiant transmittance virtually eliminated
- UV and weather-resistant material
- Extremely robust with improved slat system
- Universally applicable for different sensors
- Easy installation including mounting material for various masts
Sensor shelter with artificial ventilation
Ventilated weather and radiation protection for universal use of sensors for measuring relative humidity and air temperature. The ventilation system draws in air from the surrounding area, which is passed directly past the sensor. This prevents measurement errors caused by direct and reflected radiation, especially in calm conditions.
- Artificial ventilation of the sensors
- No return of the heated air to the ventilation circuit
- Light transmission and radiant transmittance virtually eliminated
- UV and weather-resistant material
- Extremely robust with improved slat system
- Universally applicable for different sensors
- Easy installation including mounting material for various masts
Ser[LOG] Plus Data Logger
Ser[LOG] Plus is the most versatile data logger. Thanks to its configurability and scalability, you can adapt Ser[LOG] Plus to the specific challenges of your daily measurement tasks.
Overview:
- Serial and analog sensors can be connected
- Processes up to 60 parameters
- Many state-of-the-art communication interfaces
- Extensive sensor library, freely configurable and scalable by users
- Formula collection and free formula parser
- Alarm system for 10 warning channels via built-in and external relays
- Wide range of options for exchanging information
- Interference-proof due to shielded aluminum housing
- User-friendly with free access to all connections and operating elements