THP[pro]
Temperature-Humidity-Pressure Sensor · Available from December 2024!
THP[pro]
Temperature-Humidity-Pressure Sensor · Available from December 2024!
Applications
- Global weather monitoring according to WMO standards
- Health and safety regulations
- Ship weather stations
- Helicopter decks
Find contact person
Industry-leading multisensor technology for the highest WMO standards
The quality of meteorological data is significantly influenced by the accuracy and reliability of the sensors used. The THP[pro] sensor meets the highest standards of the World Meteorological Organization (WMO) and has been developed for various applications where precise meteorological data is required.
- Three parameters in one sensor for maximum versatility
- Precision as per WMO standard: Reliable measurements, globally recognized
- Low energy requirement - perfect for low-power applications
- Fail-safe and redundant pressure measuring with three independent ICs
- Easy configuration with USB-C interface right on the sensor
- Increased operational reliability of the sensor due to integrated LED status light
Id-No.:
00.08095.300030
Meas. range air temperature:
-40...+70 °C
Meas. range rel. humidity:
0...100 % r.h.
Meas. range barometric pressure:
500...1100 hPa
Accuracy air temperature:
± 0.1 K (0…60 °C); ± 0.2 K (-40…0 °C); ± 0.2 K (60…70 °C)
Accuracy rel. humidity:
typically at 25 °C:
± 1 % (20...70 %) r. h.
± 1.5 % (0...20 %) r. h.
± 1.5 % (70...90 %) r. h.
± 3 % (90...100 %) r. h.
± 1 % (20...70 %) r. h.
± 1.5 % (0...20 %) r. h.
± 1.5 % (70...90 %) r. h.
± 3 % (90...100 %) r. h.
Accuracy barometric pressure:
typically 0.15 hPa (700... 1100 hPa)
Resolution air temperature:
0.1 °C
Resolution rel. humidity:
0.1 % r.h.
Resolution barometric pressure:
0.1 hPa
Protocols:
Modbus RTU (preconfigured); SDI-12; NMEA
Interface:
Serial RS-485; SDI-12
Supply voltage:
4.8...33 V DC
Power consumption:
Low power mode: 1 mA at 12 VDC; 4 mA at 24 VDC
Dimensions:
H 141 mm x Ø 20 mm
Housing:
Aluminum
Protection class:
IP 65 (housing)
Weight:
approx. 80 g
Standards:
DIN EN 60945
DIN EN 61000-4-2, 3, 4, 6, 11
DIN EN 61000-4-2, 3, 4, 6, 11
Accessories (order separately):
32.14567.060010 Cable 15 m, 4 pole
00.08141.600000 Sensor shelter with natural ventilation
00.08141.600000 Sensor shelter with natural ventilation
Sensor shelter with natural ventilation
For all weathers and for protection against radiation the sensor shelter with natural ventilation is designed for universal use with relative humidity and air temperature measuring instruments.
- Natural ventilation of the sensors
- No recirculation of the heated air into the ventilation circuit
- Light and radiation transmittance almost eliminated
- UV and weather resistant material
- Extremely robust with improved lamella system
- Universally applicable for different sensors
- Easy installation including mounting material for different masts