Components and accessories for a complete solution, please click here... |
| |
| Technical data |
| Standard Line |
 |
(15189) Precipitation sensors with weighing tipping bucket |
 |
Variants without heating: 00.15189.002 000 00.15189.004 000
Measuring principle: Measuring element: Measuring range/ resolution: Accuracy: Collecting surface: Range of application: Pulse output:
Housing/ funnel +ring: Dimensions/ weight: Standards: |
 |
(15189) Precipitation sensor with 2 cm³ volume of bucket (15189 W4) Precipitation sensor with 4 cm³ volume of bucket
Weighing tipping bucket system Precision stainless steel buckets acc. to Joss-Tognini 2 cm³ (2 g water) volume of tipping buckets - 0.1 mm 0...8 mm/min 4 cm³ (4 g water) volume of tipping buckets - 0.2 mm 0...16 mm/min ± 2% with intensity correction 200 cm²/ WMO standard Temperatures 0…+70°C measuring (frost resistant up to -20°C) Reed contact · polarity protected · bounce-free signal • Current consumption max. 100 µA · typical 50 µA • Supply voltage 4...30 VDC • max. load 30 VDC/ 0.5A Stainless steel aluminium · anodized H 292 mm · max. Ø 190 mm · for mounting pipe Ø 60 mm · approx. 4 kg WMO-No. 8 · VDI 3786 lf. 7 · EN 50081/82 · VDE 0100 |
| |
 |
|
Variants with heating: 00.15189.402 000 00.15189.404 000 Like above, but: Range of application: Heating data: Accuracy: Heating power: Supply voltage: |
 |
(15189 H) Precipitation sensor with 2 cm³ volume of bucket (15189 HW4) Precipitation sensor with 4 cm³ volume of bucket
Temperatures -20...+70°C • no icing · no snowdrift Electronic controlled, dual-circuit 4°C ± 2°C controlled temperature within a range of -20...+4°C 150 W 24 VDC |
| |
 |
|
For further components and accessories , please click here... |