Measuring principle: Measuring element: Measuring range/ Resolution: Accuracy:
Collecting surface: Range of application: Pulse output:
Data of heating:
Housing/ Funnel + ring: Dimensions/ Weight: Standards:
Variants: 00.15183.002 000 00.15183.004 000
On request: |
 |
Weighing tipping bucket system Precision stainless steel bucket acc. to Joss-Tognini 2 cm³-volume of bucket - 0.1 mm/ 2 g water 0...10 mm/min 4 cm³-volume of bucket - 0.2 mm/ 4 g water 0...20 mm/min ± 2% with intensity compensation controlled temperature 4°C ± 1°C within a range of -35...+4°C 200 cm²/ WMO standard Temperatures -35...+70°C Reed contact · polarity protected · bounce-free signal • Current consumption max. 100 µA · typical 50 µA • Supply voltage 4...30 VDC • max. load 30 VDC/ 0.5A Electr. controlled three-circuit heating 235 VA total heating energy 100 VA for ring 100 VA for collecting funnel 35 VA for downpipe/ bucket supply voltage 42 VAC Stainless steel aluminium, anodized H 494 mm · Ø 224 mm · for mounting pipe with Ø 60 mm · approx. 7 kg WMO-No. 8 · VDI 3786 page 7 · EN 50081/82 · VDE 0100
(1518 H3) Precipitation sensor with 2 cm³-volume of bucket (1518 H3W4) Precipitation sensor with 4 cm³-volume of bucket
(95666.1) TROPOS-100 Data Logger |