MEASURING TRANSDUCER Zurück send article to a friend print article
and Signal Releaser                                                                                              

(14953 DA) Digital-Analog-Converter for periodical signals... Id-No. 00.14953.000 000
the period duration of the input impulses of different meteorological measuring sensors is converted into
a frequency. The results of this A/D transformation are reliable and proportional to the incoming
frequency of voltage and/or current values. The pre-setting of parameter is very simple via only 4 keys.
Anemometer (1468) or wind sensor (14576 I) e. g. are connectable.
Measuring range:
Range of application:
Outputs:

Supply voltage:


Housing/ Weight




Standards:
< 10.000 Hz input frequency  < 40 µs pulse duration/ period
temperatures -25...+60°C  storing -40...+85°C
voltages: 0...10 V or 2...10 V  10 mV resolution
current: 0(4)...20 mA  20 mA resolution
196...264 V  47...63 Hz  < 5 VA (cl. 16, 18)
98...132 V  47...63 Hz  < 5 VA (Cl. 17, 18)
20.4...27.6 V  < 5 W (Cl. 11, 12/ power-line)
modular macrolon housing of  system KF
40 x 107 x 115 mm  IP 20  assembly on 35 mm standard strip and screwable by 90 mm
raster strap  removable, codable terminal clamp ·
lead < 2 x 2.5 mm²  0.4 kg
EMC according to EN 50081-2 · EN 50082-2

(8763) Two-channel transducer for parameters as ...
air temperature, air humidity, radiation and radiation balance. The sensors which can be used are
optimally adjusted and factory-made via DIP-switcher configuration.
Measuring range:
Accuracy:
Outputs:
Supply voltage:
Housing/ Weight:
-30...+70°C  0...100% r. h.  -300...0...1400 W/m² - depending on type
± 0.1% at 20°C  ± 0.5% at -30...+70°C
2 x 0(4)...20 mA  0...2 V  max. load 1.2 kΩ at 24 VDC
10...30 VDC
100 x 100 x 60 mm  IP 65  0.5 kg
Varieties:
00.08763.012 002 (8763 TH) for Temperature sensors (8241)/ (8281) · Humidity sensor (800)
00.08763.055 002 (8763 S)   for Pyranometer (16103) · (16131) ·
                                               Albedometer (1611) for direct and indirect
                                               radiation or radiation balance
00.08763.056 002 (8763 SB) for Net Radiometer (16123)
                                               for radiation and radiation balance

(14785 V) Signal Releaser for wind warning systems
The switching point is individually adjustable between 0 and 35 m/s. The relay contact closes when
exceeding a limit. When the switching hysteresis is correctly set temporary gusts can remain
unconsidered. Security and protection re given by user-specific alarm systems next in line.
Measuring range:
Accuracy:
Range of application:
Delay times:

Outputs:

Supply voltage:
Housing/ Weight:
0...35 m/s
± 1 m/s
temperatures 0...+50°C
4s* · 8s · 15s · 30s · 1 min · 2 min · 4 min · 8 min · 16 min**
a potential relay contact  1000 VA ·
max. 250 VAC ...a DC-output for an indicator · 3 Ohm
230 VAC  50 Hz  1.5 VA (others on request)
or rail- or wall mounting  75 x 55 x 110 mm  IP 40
2 diodes for operating status indication  0.4 kg
Varieties:                  inputs
00.14785.235 060
00.14785.235 210
00.14785.235 220
00.14785.235 640
00.14785.235 650
(14785 V) 0...20 mA
(14785 V) 0...1 mA  Master  e. g. for (1453 S2) · (1457 S2)
(14785 V) 0...1 mA  Slave  e. g. for (1453 S2) ·  (1457 S2)
(14785 V) 0...4 mA  Master  e. g. for (14512 G4) · (1467 G4)
(14785 V) 0...4 mA  Slave  e. g. for (14512 G4) · (1467 G4)
                                                                                                                                 *drop-out delay only **on-delay only

 
NMEA-analoge converter NAK (90249) Zurück send article to a friend print article
(90249) NMEA converter for Wind- and Weather Sensors QUATRO 
                                                                                                             Id-No. 00.90249.300 000
for connection to the Wind- and Weather Sensors QUATRO. Serial data strings of the 6 most important weather parameters are converted by the NAK into analogue output signals. An integration of the QUATRO sensors into analogue data acquisition systems is thus economically realizable.

Measuring ranges:
     Wind speed
     

     Wind direction
     rel. humidity
     Air temperature
     Dew point temp. 
     Air pressure
Accuracy:
Resolution:
Range of application:
Storage temperature:
Current output:
Voltage output:
Supply voltage:
Current consumption:

Load resistance:
Mounting:
Dimensions:
Protection class:
Interface:
Data protocols:
Baud rate:
Input rate:
EMC/ EMI


0...50 or 85 m/s (for QUATRO)
0...180 or 300 km/h
0...100 or 170 knots
0...360°
0...100% r. h.
-30...+70°C
-30...+70°C
600...900 mbar or 800...1100 mbar 0.1%/ 0.02 mA at 20°C
0.025%/ 0.005 mA
0...+50°C
-20...+85°C
0...20 mA  4...20 mA
12 VDC/ 100 mA (to supply auxiliary electronics)
18...30 VDC  reverse polarity protected
50 mA max. (without connected auxiliary)  
150 mA max. (with connected auxiliary)
max. 300 Ohm (6 Volt)
DIN rail NS-35
73 x 49 x 53 mm
IP 20
RS 422/ 485 listener mode
seriell acc. to NMEA 0183: $WIMWV $WIMHU $WIMTA $WIMMB
4.800 baud 8 N 1
max. 4 Hz
IEC 61000-6-2 IEC 61000-6-4