Heated precipitation sensors (1518 H3++) with additional functions Zurück send article to a friend print article
Heated Precipitation sensor (1518 H3++)...
              ... with linearised impulse output
              ... with analogue output signals
   
At first view...
and visual it looks like sensors of the type (1518 H3), but...

• A high degree of solutions is provided in one device ...
      · You can adjust several operation modes
      · You can use impulse and/ or analogue output signals
      · You can choose the measuring range depending on situation
      · You can operate in the low-power mode
• Bounce-free, linearised impulse output
• Analogue mA- or Volt output signals

The heated precipiation sensors (1518 H3++) can either be used...
... up to -35 °C operating temperature and
... as part of automatic weather station or
... connected to PLC systems or
... together with other data acquisition systems.
  Click here for a request...

Technical data  
Professional Line (1518 H3++) Heated Precipitation Sensors with additions...
Variants:
00.15183.002 050
00.15183.004 050


Measuring principle:
Measuring element:
Meas. range/ resolution:

Accuracy:
Collecting surface:
Range of application:
Heating data:



Housing/funnel+ring:
Dimensions/ weigth:
Standards:

Analogue outputs:
Current consumption:
Supply voltage:

Impulse output:
(at deactivated analogue output)
Current consumption:
Supply voltage:
Switch load:

(1518 H3++)      Heated precipitation sensor · with 2 cm³ bucket
(1518 H3W4++) Heated precipitation sensor · with 4 cm³ bucket

Weighing tipping bucket
Pecision stainless steel tipping bucket designed acc. to Joss Tognini
2 cm³- (2 g water) volume of bucket - 0.1 mm • 0...10 mm/min
4 cm³- (4 g water) volume of bucket - 0.2 mm • 0...20 mm/min
± 2%
200 cm² / WMO standard
Temperatures -35...+70°C
Electr. controlled 3-circuit precision heating system • heating power 235 W:
100 W collecting ring · 100 W funnel · 35 W drain pipe/ bucket •
Controlled temperature 4°C ± 1°C within a range of  -35°C...+4°C •
42 VAC supply voltage
Stainless steel  aluminium · anodised
Approx. H 494 mm · Ø 224 mm • for mast mounting Ø 60 mm • approx. 7 kg
WMO-No. 8 • VDI 3768 lf. 7 • EN 50081/82 • VDE 0100

0...20 mA · 4...20 mA • 0...5/10 V - adjustable
≤ 40 mA
18...30 VDC • max. load 600 Ω

Linearised, bounce-free output signal

Max. 100 µA · typical 50 µA
5...30 VDC
Max. 30 VDC/ max. 0.5 A at pure ohm load
   
Basic settings:
Active impulse output:
Measuring range:
Active analogue output:
Current consumption:
Supply voltage:
 
Linearised, bounce-free output signal
0...10 mm
0...20 mA
≤ 40 mA
18...30 VDC • max load 600 Ω
   
  Accessories for the precipitation sensors (1518 H3++)...