| Technical data |
 |
|
| Professional Line |
 |
(15188++) Precipitation sensors with additional functions |
 |
 |
 |
Variants without heating: 00.15188.002 050 00.15188.004 050
Measuring principle: Measuring element: Measuring range/ resolution:
Accuracy: Collecting funnel: Range of application: Housing/ funnel+ring: Dimensions: Weight: Standards:
Analogue outputs: Current consumption: Supply voltage: DC
Impulse output: (at deactivated analogue output) Current consumption: Supply voltage: DC Switch load:
|
 |
(15188++) Precipitation sensor · with 2 cm³ bucket (15188 W4++) Precipitation sensor · with 4 cm³ bucket
Weighing tipping bucket Precision stainless steel bucket designed acc. to Joss Tognini 2 cm³ (2 g water) volume of bucket - 0.1 mm • 0...10 mm/min 4 cm³ (4 g water) volume of bucket - 0.2 mm • 0...20 mm/min ± 2% 200 cm² • WMO standard Temperatures 0...+70°C · measuring Stainless steel • aluminium · anodised Approx. H 395 mm · max. Ø 190 mm • for mounting on a mast Ø 60 mm Approx. 4 kg WMO-No. 8 • VDI 3768 fl. 7 • EN 50081/82 • VDE 0100
0...20 mA · 4...20 mA • 0...5/10 V - adjustable ≤ 40 mA 18...30 VDC • max. load 600 Ω
Linearised, bounce-free output signal
Max. 100 µA · typical 50 µA 5...30 VDC Max. 30 VDC/ max. 0.5 mA at pure ohm load
|
Variants with heating: 00.15188.202 050 00.15188.204 050
Range of application: Heating data:
|
 |
(15188 H++) Precipitation sensor · with 2 cm³ bucket (15188 HW4++) Precipitation sensor · with 4 cm³ bucket
Temperatures -30...+70°C · no icing · no snowdrift Electr. controlled dual-circuit heating system • Controlled temperature of 4°C ± 2°C within a range of -20...+4°C Heating power 170 W: 100 W funnel · 70 W outlet/ tipping bucket Supply voltage: 42 VAC |
Basic settings: Active impulse output: Measuring range: Active analogue output: Current consumption: Supply voltage: |
 |
Linearised, bounce-free output signal 0...10 mm 0...20 mA ≤ 40 mA 18...30 VDC · max. load 600 Ω |
| |
 |
Accessories for Precipitation sensors (15188++) |