| Standard Line |
 |
Wind Sensors INDUSTRY |
 |
Measuring principle: Range of application: Supply voltage: Housing:
Included in delivery:
|
 |
Hall sensor array Temperatures -30...+70°C heated wind speed 0...60 m/s 24 VDC (20...28 VDC) · max. 800 mA heating · electr. controlled · 18 W Seawater-resistant aluminium · anodized · IP 53 · Ø 32 mm · bore Ø 30 mm for mounting at traverse 1 sensor • 1 cable for plug connection · 12 m · ready-made
The wind sensors are connectable to data loggers and ! |
| |
 |
|
| Parameters: |
 |
Wind direction (14567) |
 |
Wind speed (14577) |
 |
 |
Measuring element:
Measuring range: Accuracy: Resolution: Starting value: Outputs:
Dimensions: Weight:
|
 |
Blade wind vane stably fibre-reinforced plastics 0...360° < ± 2% 5.6° < 0.7 m/s 0/4...20 mA max. load 600 Ω
Wind vane L 232 mm · H 307 mm Approx. 0.35 kg |
 |
3-armed cup rotor fail-safe
0.7...50 m/s ± 2% FS < 0.02 m/s < 0.7 m/s 0/4...20 mA = 0...50 m/s max. load 600 Ω compensated Cup rotor R30 mm · H 230 mm Approx. 0.25 kg |
Varieties: Output 0...20 mA Output 4...20 mA |
 |
Id-No. 00.14567.100 000 00.14567.100 040 |
 |
Id-No. 00.14577.100 000 00.14577.100 040 |
| |
 |
|
 |
|
Low power wind sensors with 0...2 V output (without heating) |
Id-No. Measuring ranges: Current consuption: |
 |
00.14567.100 060 0...360° 4 mA |
 |
00.14577.100 060 0.7...35 m/s 6 mA |
Range of application: Supply voltage: Output: |
 |
Temperatures 0...+70°C • -30...+70°C at non icing conditions 10...28 VDC 0...2 VDC |
Accessories: 32.14567.006 000 32.14567.010 000 |
 |
Masts and Power supply units see chapter (14567 U6) Mast adapter · Ø 50 mm (14567 U10) Traverse
Test report or test certificate available on request. |