Lambrecht meteo
LAMBRECHT meteo GmbH
Friedländer Weg 65-67
37085 Göttingen
Tel.: +49-(0)551-4958-0
Fax: +49-(0)551-4958-312
E-Mail: info@lambrecht.net
Internet: http://www.lambrecht.net
Home > Precipitation > Water Supply > Precipitation sensor according to Joss-Tognini (15189)

Precipitation sensor according to Joss-Tognini (15189)

Developed through experience ...

and equipped with the features and advantages of the proven forerunners, the weighing sensor (15189) is the “class winner”! Its functionality meets exactly the demands of classical meteorology and hydrology, as well as semi-professional industrial meteorology. The sensor (15189) and its variaties are a very efficient and economical lifelong investment!

  • best price-performance ratio in its class!
  • single device or part of an automatic weather station
  • connectable to Lambrecht's data loggers
  • very reliable, weighing measuring system
  • high quality materials
  • easy installation

 

measurement of precipitation amount Analogue output integrated linearisation of the output signal 3 heating circuits, Measuring edge with 100 W, funnel with 100 W and heated drain with 70 W Sensor and housing parts made of metal

Your contact person

Daniel Dreilich
+49 551 4958-395
ddreilich@lambrecht.net
  Precipitation sensor according to Joss-Tognini (15189)
Id-No. 00.15189.002 000 Sensor with 2 cm³ bucket, unheated
00.15189.004 000 Sensor with 4 cm³ bucket, unheated
00.15189.402 000 Sensor with 2 cm³ bucket, heated
00.15189.404 000 Sensor with 4 cm³ bucket, heated
Measuring range 2 cm³: 0...8 mm/min • 4 cm³: 0...16 mm/min
Accuracy ± 2 % with intensity correction
Resolution 2 cm³: (~2 g) volume of tipping bucket - 0.1 mm • 4 cm³: (~4 g) volume of tipping bucket - 0.2 mm
Pulse output reed contact • polarity protected • bounce-free signal • supply voltage 4...30 V • current consumption max. 100 μA • typical 50 μA • load max. 30 VDC / 0.5 A
Collecting surface area 200 cm²/ WMO standard
Heating data electr. controlled dual-circuit heating • supply voltage 24 VDC • controlled temperature of 4 ± 2 °C within a range of -20...+4°C • heating power 150 W
Dimensions H 292 mm • Ø 190 mm • for mounting pipe Ø 60 mm
Housing aluminium • anodised
Weight approx. 3 kg
Standards WMO-No. 8 • VDI 3786 page 7 • EN 50081/82 • VDE 0100
Accessories Masts, dirt pan, protection ring, connecting cables, data logger and evaluation software • (1496 S62) Power supply unit for heated sensors