Lambrecht meteo
LAMBRECHT meteo GmbH
Friedländer Weg 65-67
37085 Göttingen
Tel.: +49-(0)551-4958-0
Fax: +49-(0)551-4958-312
E-Mail: info@lambrecht.net
Internet: http://www.lambrecht.net
Home > Precipitation > Flood Protection > Precipitation sensor according to Joss-Tognini (15189 serial)

Precipitation sensor according to Joss-Tognini (15189 serial)

The successful precipitation sensor ...

now available with serial interface. The resistent and beautifully designed sensor has an additional linearised pulse output for high accuracy and easy connection to external data loggers. This new sensor provides intensity adjusted measurement of precipitation with serial measurand output via RS485.

  • SDI-12 protocol (at RS485) for universal use
  • interface RS 485
  • LBP protocol (Lambrecht Bus Protocol)
  • integrated intensity adjustment
  • calculation of the precipitation sum since last data call
  • calculation of the precipitation intensity for a gliding minute
  • calculation of the precipitation intensity for a gliding hour (minute interval)

 

measurement of precipitation amount Digital output RS485 digital input

Your contact person

Daniel Dreilich
+49 551 4958-395
ddreilich@lambrecht.net
  Precipitation sensor according to Joss-Tognini (15189 serial)
Id-No. 00.15189.002 060 Sensor with 2 cm³ bucket, unheated
00.15189.004 060 Sensor with 4 cm³ bucket, unheated
00.15189.402 060 Sensor with 2 cm³ bucket, heated
00.15189.404 060 Sensor with 4 cm³ bucket, heated
Measuring range 2 cm³: (2 g) volume of tipping bucket - 0.1 mm • 4 cm³: (4 g) volume of tipping bucket - 0.2 mm
Accuracy ± 2 %
Resolution 2cm³: 0...8 mm/min • 4cm³: 0...16 mm/min
Interface RS485 • SDI-12 protocol (at RS485) • LBP protocol (Lambrecht Bus Protocol)
Collecting surface area 200 cm²/ WMO standard
Supply voltage 10...30 V DC (12 V DC/ 24 V DC)
Heating data *electr. controlled dual-circuit heating • controlled temperature of 4 ± 2 °C within a range of -20...+4 °C • heating power 150 W • supply voltage 24 V DC
Dimensions H 292 mm • Ø 190 mm • for mounting pipe Ø 60 mm
Housing aluminium • anodised
Weight approx. 2.5 kg
Standards WMO-No. 8 • VDI 3786 page 7 • EN 50081/82 • VDE 0100
Accessories (1496 S62) Power supply unit for heated sensors